NORD Drivesystems BU0200 User Manual

Page 207

Advertising
background image

SK 200E Manual for frequency inverters

206

Subject to technical alterations

BU 0200 GB-4411

Parameter

{Factory setting}

Setting value / Description / Note

Device

Supervisor

Parameter
set

16 = Reference value Ain1,

SK 2x0E:
Setpoint AIN1 of the FI is compared with the value in
(P435[-01 or -02]).
SK 2x5E: Setpoint AIN1 of the 1st IO extension is compared with the
value in (P435[-01]).

17 = Reference value Ain2,

SK 2x0E:
Setpoint AIN2 of the FI is compared with the value in
(P435[-01 or -02]).
SK 2x5E: Setpoint AIN2 of the 1st IO extension is compared with the
value in (P435[-01]).

18 = Inverter ready: The FI is in standby state. After being enabled it gives

an output signal.

High

19 = ... 29 reserved

For Posicon functions see BU 0210

30 = Status Digital-In 1*

High

Details for the

use of the bus

systems can be

found in the

relevant

supplementary

bus manual.

31 = Status Digital-In 2*

High

32 = Status Digital-In 3*

High

33 = Status Digital-In 4*

High

39 = STO inactive *

High

*) (P546[-

01]…[-03]) = 20

P435

[-01]

[-02]

Dig. out. scaling

(Scaling of digital outputs)

-400 ... 400 %

{ 100 }

[-01] =

Digital output 1, Digital output 1 of the frequency inverter

[-02] =

Digital output 2, Digital output 2 of the frequency inverter (only SK 2x0E)

Adjustment of the limit values of the output function. For a negative value, the output function
will be output negative.

Reference to the following values:

Current limit (3) = x [%]

P203 >Rated motor current<

Torque current limit (4) = x [%]

P203

P206 (calculated rated motor torque)

Frequency limit (5) = x [%]

P201 >Rated motor frequency<

P436

[-01]

[-02]

Dig. out. hysteresis

(Hysteresis of digital outputs)

S

0 ... 100 %

{ 10 }

[-01] =

Digital output 1, Digital output 1 of the frequency inverter

[-02] =

Digital output 2, Digital output 2 of the frequency inverter (only SK 2x0E)

Difference between switch-on and switch-off point to prevent oscillation of the output signal.

P460

Watchdog time

(Time watchdog)

S

0.0 / 0.1 ... 250.0 s

{ 10.0 }

0.1 ... 250.0 = The time interval between the expected watchdog signals (programmable

function of digital inputs P420

– P425). If this time interval elapses without a

pulse being registered, switch off and error message E012 are actuated.

0.0 = Customer error: As soon as a high-low flank or a low signal is detected at a digital

input (function 18) the FI switches off with error message E012.