6.2.2

Information (I/O - extension)

Parameter

Setting value / Description / Note

Device

Supervisor

Parameter
set

P170

... [-01]

... [-02]

Present errors

(Present errors)

0 ... 9999

Actual fault present. Further details in Section 7 "Operating status messages".

… [-01 ] = Actual module fault

… [-02 ] = Last module fault

Possible displayed values:

1000 = EEPROM error

1030 = Systembus Bus Off

2000 = DIP changed

2001 = DIP configuration error / not permissible

2010 = Analog output error

2020 = Inverter does not support SK xU4-IOE

(Error not associated with SK 2xxE possible)

P171

... [-01]

...

... [-03]

Software version

(Software Version / Revision)

0.0 ... 9999.9

This parameter shows the software and revision numbers in the module. Array [-03] provides
information about any special versions of the hardware or software A zero stands for the
standard version.

… [-01] = Software Version 1, "Version number":

(e.g.: V1.0)

… [-02] = Software Version 2, "Revision number": (e.g.: R1)

… [-03] = Software Version 3, "Special version":

(e.g.: 0)

P172

Configuration

(Configuration level)

0 ... 2

This parameter displays the functions or variants integrated into the module.

1 = Internal bus module (SK CU4-

…)

2 = External bus module (SK CU4-

…)

3 = BUS Technology Unit via SPI