NORD Drivesystems BU0200 User Manual

Page 198

Advertising
background image

6 Parameterisation

BU 0200 GB-4411

Subject to technical alterations

197

Parameter

{Factory setting}

Setting value / Description / Note

Device

Supervisor

Parameter
set

P402

[-01]

...

[-06]

Adjust: 0%

(Analog input adjustment: 0%)

S

-50.00 ... 50.00 V

{ all 0.00 }

[-01] =

Ext analog in 1, "External analog input 1", AIN1 of the first I/O extension
(SK xU4-IOE).

[-02] =

Ext analog in 2, "External analog input 2", AIN2 of the first I/O extension
(SK xU4-IOE).

[-03] =

Ext. A.in 1 2nd IOE, "External analog input 1 2nd IOE", AIN1 of the second I/O
extension (SK xU4-IOE) (= analog input 3).

[-04] =

Ext. A.in 2 2nd IOE, "External analog input 2 2nd IOE", AIN1 of the second I/O
extension (SK xU4-IOE) (= analog input 4).

[-05] =

Analog input 1, Analog input 1 (only SK 200E, SK 210E)

[-06] =

Analog input 2, Analog input 2 (only SK 2x0E)

... only with
SK CU4-IOE or
SK TU4-IOE

This parameter sets the voltage which should correspond with the minimum value of the
selected function for the analog input 1 or 2. In the factory setting (setpoint) this value is
equivalent to the setpoint set via P104 >Minimum frequency<.

Note
SK 2x0E
For the adjustment of the integrated analog inputs of the SK2x0E to the type of analog signals,
the following values must be set:

0 - 10V

→ 0.00 V

2 - 10V

→ 2.00 V

0 - 20mA

→ 0.00 V (Set internal resistance via DIP switch (Section: 5.2.2.2)!)

4 - 20mA

→ 1.00 V (Set internal resistance via DIP switch (Section: 5.2.2.2)!)

SK xU4-IOE
Standardisation to typical signals, such as 0(2)-10V or 0(4)-20mA is carried out via the
DIP switch on the I/O extension module. In this case, additional adjustment of
parameters (P402) and (P403) must not be carried out.

P403

[- 01]

...

[- 06]

Adjust: 100%

(Analog input adjustment: 100%)

S

-50.00 ... 50.00 V

{ all 10.00 }

[-01] =

Ext analog in 1, "External analog input 1", AIN1 of the first I/O extension
(SK xU4-IOE).

[-02] =

Ext analog in 2, "External analog input 2", AIN2 of the first I/O extension
(SK xU4-IOE).

[-03] =

Ext. A.in 1 2nd IOE, "External analog input 1 2nd IOE", AIN1 of the second I/O
extension (SK xU4-IOE) (= analog input 3).

[-04] =

Ext. A.in 2 2nd IOE, "External analog input 2 2nd IOE", AIN1 of the second I/O
extension (SK xU4-IOE) (= analog input 4).

[-05] =

Analog input 1, Analog input 1 (only SK 200E, SK 210E)

[-06] =

Analog input 2, Analog input 2 (only SK 2x0E)

... only with
SK CU4-IOE or
SK TU4-IOE

This parameter sets the voltage which should correspond with the maximum value of the
selected function for the analog input 1 or 2. In the factory setting (setpoint) this value is
corresponds with the setpoint set via P105 >Maximum frequency<.

Note
SK 2x0E
For the adjustment of the integrated analog inputs of the SK2x0E to the type of analog signals,
the following values must be set:

0 - 10V

→ 10.00 V

2 - 10V

→ 10.00 V

0 - 20mA

→ 5.00 V (Set internal resistance via DIP switch (Section: 5.2.2.2)!)

4 - 20mA

→ 5.00 V (Set internal resistance via DIP switch (Section: 5.2.2.2)!)

SK xU4-IOE