NORD Drivesystems BU0200 User Manual

Page 305

Advertising
background image

SK 200E Manual for frequency inverters

304

BU 0200 GB-4411

IT network ............................. 41, 44

J

Jog frequency (P113) ................ 181

Jumper ........................................ 44

K

KTY84 ....................................... 158

L

Language selection ................... 140

Last fault (P701) ........................ 229

Last frequency error (P702) ...... 229

Leakage current ........................ 290

LEDs ................................... 85, 109

Lifting equipment with brake ..... 178

Limit

Field current controller (P317)

.......................................... 189

Torque current controller (P314)

.......................................... 189

Linear V/f characteristic curve ... 186

Link circuit last error (P705) ...... 230

Load dropping ........................... 178

Load factory setting ........... 216, 238

Load monitoring ........................ 219

Load monitoring delay (P528) ... 218

Load monitoring frequency (P527)

.............................................. 217

Load monitoring Max. (P525) .... 217

Load monitoring Min. (P526) ..... 217

Load monitoring mode (P529)... 218

Low Voltage Directive ................... 3

M

M12 flanged connector ............... 57

M12-Connections ...................... 106

Mains connection ........................ 41

Mains filter .................................. 44

Mains unit ................................. 103

Maintenance ............................. 299

Maintenance switch .................. 126

Master function output (P503) ... 212

Master function value (P502) .... 211

Master-Slave ............................. 211

Maximum frequency (P105) ...... 176

Maximum frequency auxiliary

setpoint (P411) ..................... 198

Mechanical power (P727)......... 233

Memory Module 127, 225, 227, 256

Menu group .............................. 170

Messages ......................... 127, 259

Min. system bus cycle time (P153)

............................................. 238

Minimum frequency (P104) ...... 176

Minimum frequency auxiliary

setpoint (P410) ..................... 198

Minimum frequency process

controller (P466) ................... 207

Mode

Analog input (P401) ............. 195

Fixed frequency (P464) ........ 207

Modulation depth (P218) .......... 185

Motor

cos phi (P206) ...................... 183

Nominal current (P203) ........ 183

Nominal frequency (P201) .... 182

Nominal power (P205).......... 183

Nominal speed (P202).......... 182

Nominal voltage (P204) ........ 183

Star Delta connection(P207) 183

Motor cable length ...................... 42

Motor data ................ 148, 182, 293

Motor list (P200) ....................... 182

Motor mounted ........................... 29

Motor Temperature .................. 158

Motor type .................................. 10

Mounting the SK 2xxE ................ 23

Multiple motor operation ............. 42

N

No load current (P209) ............. 183

Nominal value process controller

(P412) .................................. 199

NORD CON .............................. 256

O

Offset analog output (P417) ..... 199

Operating display (P000) ......... 173

Operating displays ................... 173

Operating mode ....................... 273

Operating status ............... 127, 259

Operating time (P714) .............. 231

Operating time, last fault (P799)237

Operation .................................. 127

Option (mounting) locations ........ 26

Option monitoring (P120) ......... 181

Options ....................................... 67

Oscillation damping (P217) ...... 185

Outdoor installation .................... 66

Output voltage monitoring (P539)

............................................. 221

Overcurrent ...................... 261, 267

Overtemperature .............. 260, 267

Overvoltage .............................. 261

Overvoltage switch-off ................ 33

P

P - limit chopper (P555) ............ 226

P factor torque limit (P111) ....... 180

Parameter identification (P220) 187

Parameter loss ......................... 262

Parameter overview ................. 242

Parameter set

Last error (P706) .................. 230

Parameter set (P731) ........... 233

Parameter set (P100) ............... 175

Parameter storage mode (P560)

............................................. 227

ParameterBox

Error messages .................... 145

Operation .............................. 137

Parameters ........................... 143

Parameterisation .............. 135, 168

Frequency inverter................ 170

I/O extension ........................ 238

ParameterBox ...................... 141

Parameterisation adapter ......... 256

P-component of PI controller

(P413) ................................... 199

PI process controller ................. 282

Plug connectors for control

connection .............................. 57

Plug connectors for power

connections ............................ 55

Plug connectors: ......................... 55

Advertising