3 details of the sk 2x5e control connections – NORD Drivesystems BU0200 User Manual

Page 52

Advertising
background image

2 Assembly and installation

BU 0200 GB-4411

Subject to technical alterations

51

2.8.3

Details of the SK 2x5E control connections

Control voltage 24V external! Terminal 44. If the frequency inverter is not equipped with an optional mains
unit it must be supplied with an external 24V voltage.

For devices where the AS interface is used (SK 225E and SK 235E), the control voltage supply must be
provided via the yellow AS interface cable. In this case however, the frequency inverter must not have an
additional supply via Terminal 44 in order to prevent damage to the mains unit or the AS interface bus.

Terminal/

Name

Function

{Factory setting}

Data

Description / wiring suggestion

Parameter


SK 205E, SK 215E, SK 225E, SK 235E

44

24V

24V supply

Input

24VDC ± 25%

200mA (FI without
accessories) ... 800mA
according to load on the
inputs and outputs or
equipment with options

24VDC, max 60mA

Output voltage with use of
the AS interface

Supply voltage connection for the
FI control unit and the output
DOUT1

With SK 225/235E and use of the
AS interface (yellow cable) the
inverter is supplied by the AS
interface.

-

40 GND / 0V

Reference potential
for digital signals

-

21

DIN1

Digital input 1

{ON right}

Digital input as per
EN 61131-2 Type 1

Low: 0-5V

(~ 9.5k

Ω)

High: 15-30V

(~ 2.5-3.5k

Ω)

Input capacitance:
Input 1 + 4 = 10 nF
Input 2 + 3 = 1.2 nF

Scan time: 1ms

Reaction time:

≥ 4ms


HTL encoder connection
only to DIN2 and DIN3
possible
Frequency limits:
max. 205 kHz

min. 250 Hz

44

40

21

22

23
24

18

… 30V

GND / 0V

Inputs 1 + 4 react slowly

Inputs 2 + 3 react quickly

P420 [01]

22

DIN2

Digital input 2

{ON left}

P420 [02]

23

DIN3

Digital input 3

{fixed frequency 1,
(P465[-01])}

P420 [03]

24

DIN4

(only SK205/225E)

Digital input 4

{fixed frequency 2,
(P465 [-02])}

P420 [04]

1

DOUT1

Output 1

{Fault}

Digital output

18-30V, each to VI 24V

max. 200mA

max. 100k

load

For evaluation in a control system.

With SK 225/235E and use of the
AS interface (yellow cable),
DOUT1 must not be under load.

P434 [01]

38

TF+

PTC resistor input

-

For monitoring motor temperature
with PTC

A shielded cable must be used for
separate mounting of the motor
and the FI (note cable length).

-

39

TF-

PTC resistor input

Advertising