6 Parameterisation

BU 0200 GB-4411

Subject to technical alterations

173

6.1.1

Operating displays

The abbreviations used are described in Section 9.13

“Abbreviations in this Manual".

Parameter

{Factory setting}

Setting value / Description / Note

Device

Supervisor

Parameter
set

P000

Operating para

.

disp.

(Operating parameter display)

0.01 ... 9999

In the SimpleBox (SK CSX-3H) display, the parameter value online selected in P100 is
displayed.

P001

Select of disp. value

(Selection of display value)

0 ... 63

{ 0 }

0 = Actual frequency [Hz]: the current output frequency being supplied by the FI.

1 = Speed [1/min]: the current rotation speed as calculated by the FI.

2 = Setpoint frequency [Hz]: the output frequency equivalent to the actual setpoint. This

need not match the actual output frequency.

3 = Current [A]: the actual output current measured by the FI.

4 = Torque current [A]: the torque developing output current of the FI.

5 = Voltage [Vac]: the actual alternating voltage being output by the FI.

6 = DC link voltage [V DC], "Link circuit voltage": is the internal DC voltage of the FI.

Amongst other things, this depends on the level of the mains voltage.

7 = cos phi, "cos

": is the actual calculated value of the power factor.

8 = Apparent power [kVA]: the current apparent power calculated by the FI.

9 = Real power [kW]: the current effective power calculated by the FI.

10 = Torque [%]: the current torque calculated by the FI.

11 = Field [%]: the current field in the motor calculated by the FI.

12 = On-time [h], "Operating hours": time that voltage is applied to the FI network.

13 = Run-time [h], "Operating hours enabled": is the time that the FI is enabled.

14 = Analog input 1 [%]: actual value AIN1 of the first I/O extension SK xU4-IOE.

15 = Analog input 2 [%]: actual value AIN2 of the second I/O extension SK xU4-IOE.

16 =

… 18 reserved

Posicon, BU 0210

19 = Temp. of heat sink [°C], "Heat sink temperature": current temperature of the FI heat sink.

20 = Usage rate motor [%]: average motor load, based on the known motor data

(P201...P209).

21 = Usage rate brakeres. [%], "Brake resistor load": is the average braking resistor load,

based on the known resistance data (P556...P557).

22 = Internal temperature [°C]: current temperature in FI housing.

23 = Motor temperature [°C]: only in combination with the analog input and appropriate

wiring (KTY84).

30 = Cur. set value MP-S [Hz], "Actual setpoint value of the motor potentiometer function

with saving": display of the setpoint which can be set in advance (without the drive unit
running) via the motor potentiometer function 71 / 72 (See parameter P420).

50 =

… 54 reserved

Posicon, BU 0210

60 = R Stator Ident: stator resistance, automatic determination of motor data, P220

61 = R Rotor Ident: rotor resistance, automatic determination of motor data, P220

62 = L Scat Stator Ident, "L Scatter Stator Ident": stator leakage inductance, from automatic

determination of motor data, P220

63 = L Stator Ident: stator inductance, from automatic determination of motor data, P220