Publication 1758-UM002D-EN-P - October 2010

Extension Modbus Protocol for DataSite Controllers (1758-FLO) 277

Modbus Registers for the Power Shutdown Time

These registers record the previous shutdown time of the controller.

Modbus Registers for Reading Gas Component Parameters

The gas component parameters can be read from a gas component analyzer
automatically by using Modbus Master scan blocks. Refer to

Settings on page

35

for details on using the Modbus Master scan block. The registers on the

following table are used for saving the parameters read from the gas
component analyzer.

Modbus registers for power shutdown time

Description

Data Type

Modbus Address

Hour for power off

u_short

32911

Minute for power off

u_short

32912

Second for power off

u_short

32913

Modbus registers for reading gas component parameter

Modbus Addresses in 1758-FLO Controller

Description

Datasite FLO used
register

user defined register
when using Modbus
Master Scan

32159…32200

48001…48050

Component of meter run 0 (see

Offset

structure table on page 277

)

32259…32300

48051…48100

Component of meter run 1

32359…32400

48101…48150

Component of meter run 2

32459…32500

48151…48200

Component of meter run 3

32559…32600

48201…48250

Component of meter run 4

32659…32700

48251…48300

Component of meter run 5

32759…32800

48301…48350

Component of meter run 6

32859…32900

48351…48400

Component of meter run 7

Offset structure table

Data Type

Offset

Name

Description

float

0

CH4

Methane

float

1

N2

Nitrogen

float

2

CO2

Carbon dioxide

float

3

C2H6

Ethane