Publication 1758-UM002D-EN-P - October 2010

302 Extension Modbus Protocol for DataSite Controllers (1758-FLO)

49036

u_short

R

Units of measurement
0: U.S.
1: Metric

49037

u_short

R

Accumulate
0: Do not accumulate
1: Accumulate

49038

u_short

R

Use automatic components analysis
instrument
0: Disable
1: Enable

49039

u_short

R

Calculation type
0: AGA3
1: AGA7

49040

u_short

R

Algorithm for the calculation of the
compressibility factor
0: Gas Analysis
1: HV-GR-CO2
2: GR-CO2-N2

49041

u_short

R

Run interval

49042

u_short

R

Base Multiplier Period (BMP)

49043

float

R

Contract standard reference ratio pressure

49045

float

R

Contract standard reference ratio
temperature

49047

float/u_int

R

Cut-off differential pressure, cut-off pulse

49049

u_short

R

Pressure type
0: Gauge
1: Absolute

49050

float

R

Atmospheric pressure

49052

u_short

R

Tap location
0: Upstream
1: Downstream

49053

u_short

R

Orifice material
0: Type 304&316 stainless steel
1: Monel
2: Carbon Steel

49054

float

R

Orifice diameter

49056

float

R

Orifice reference temperature

49058

u_short

R

Tube material
0: Type 304&316 stainless steel
1: Monel
2: Carbon Steel

49059

float

R

Tube diameter

49061

float

R

Tube reference temperature

Parameters for command number 18 (Continued)

Address

Data Type

Attribute

Description