Extension Modbus Protocol for DataSite Controllers (1758-FLO) 303

There is no event code for command number 18.

Command Number 19: Set Up the Gas Component Parameter

Use command number 19 to set up the gas component parameters for each
meter run.

49063

u_short

R

Relative density type
0: Relative density
1: Ideal density

49064

float

R

Relative density

49066

float

R

Reference pressure for measuring relative
density

49068

float

R

Reference temperature for measuring
relative density

49070

float

R

AGA8 gas heating value

49072

float

R

Reference temperature for gas heating
value

49074

u_short

R

Interval for collecting the components from
analysis instrument automatically (valid
only when automatic component analysis
instrument setting is enabled)

Return codes for command number 18

Return Code

Description

00

OK

01

Meter run is invalid

100

Pass code is incorrect

Other

Invalid

Parameters for command number 19

Address

Data Type

Attribute

Description

49025

u_short

RW

19

49026

u_short

R

Return code
0: OK

49027

u_short

W

Meter run (0…7)

49028

u_int

W

Pass code for user

49030…49034

Reserved

49035

float

W

CH4

49037

float

W

N2

Parameters for command number 18 (Continued)

Address

Data Type

Attribute

Description