Program Table Mode (Mode 0)

5-47

5.7

Program Table Mode (Mode 0)

5.7.1 Program Table Mode Setting

Set the /MODE 0/1 input signal to Mode 0 for Program Table Mode. The following parame-
ter is used to define the /MODE 0/1 input signal.

5.7.2 Program Operation Inputs Setting

The following parameters are used to define the inputs used in the program table operation.

Table 5.4:

Parameter

Signal

Pin No.

Setting

Default

Pn803

/Mode 0/1

CN4-3

0 = Input signal Closed = Mode 0
1 = Input signal Open = Mode 0
2 = Always Mode 0
3 = Always Mode 1

0

Table 5.5:

Parameter

Signal

Pin No.

Setting

Default

Pn804

/START – STOP

CN4-5

0 = Input Signal Closed = Motor Start, Program Start
1 = Input Signal Open = Motor Stop, Program Stop
2 or 3 = No Program Start

0

Pn805

/PGMRES

CN4-7

0 = Input Signal Open

o

Closed = Program Reset

1 = Input Signal Closed

o

Open = Program Reset

2 or 3 = No Program Reset

0

Pn806

/SEL0

CN4-9

0 = Input signal Closed = Program Select
1= Input Signal Open = Program Select
2 = Always Program Select
3 = No Program Select

0

Pn807

/SEL1

CN4-11

Pn808

/SEL2

CN4-13

Pn809

/SEL3

CN4-15

Pn80A

/SEL4

CN4-17

Pn833

/SEL5

CN1-41

Pn834

/SEL6

CN1-45