5 program table operation commands – Yaskawa Sigma II Indexer User Manual

Page 155

Advertising
background image

Sigma II Indexer User’s Manual

Serial Command Functions

6-26

6.5.5 Program Table Operation Commands.

Table 6.9: Program Table Operation

Serial Command

Function / Description

Answer

START

Program Operation Restart

Command restarts program step of program
table last reserved by START sss. If no program
step is reserved, start program step 0. Also
restarts program step interrupted by STOP com-
mand.

sss = Program Step

Positive Response: OK

Negative Response: ExxE

STARTss
0

d sss d 127

Program Operation Start

Starts program step sss.

Command operation equivalent to /START-
STOP signal input operation.

sss = Program Step

Positive Response: OK

Negative Response: ExxE

STOP

Program Operation Interruption

Command interrupts program table operation.

Command operation equivalent to /START-
STOP signal input operation.

Positive Response: OK

PGMRES

Program Reset

Command resets reserved program step when
program operation is interrupted.

Command operation equivalent to /PGMRES
signal input operation.

Positive Response: OK

Advertising