Yaskawa Sigma II Indexer User Manual

Page 179

Advertising
background image

Sigma II Indexer User’s Manual

Sigma II Indexer Status Display Table

9-8

Error

4

E54E

A.9F

Servo ON Incomplete Error

Servo is not enabled. Turn servo on.

ON

ON

No Change

E55E

A.9F

Servo ON Failure Error

SGDH failed to turn ON servo. Check to see
if main power is ON or if SGDH is in the
alarm state.

Cannot execute a ST, start, command during
program operation, etc.

ON

ON

No Change

E56E

A.9F

Serial Communication Non Definition
Command Error

Command syntax error.

ON

ON

No Change

E57E

A.9F

Address “Out of Range” Error

Serial command address is out of range.

ON

ON

No Change

E58E

A.9F

Data “Out of Range” Error

Serial command data is out of range.

ON

ON

No Change

E59E

A.9F

Communication Failure Error between
NS600 and SGDH

Communication error between NS600 and
SGDH. Cannot send commands via CN6
when CN3 is in use.

ON

ON

No Change

E5AE

A.9F

Execution Disable Error while Servo ON

Some functions can only be executed when
servo is off:
1) Origin search (Fn003)
2) Absolute encoder reset (Fn008 or
ABSPGRES)
3) Jog mode operation (Fn002)
4) Automatic zero adjustment of motor cur-
rent detection signal (Fn00E or CURZERO)
5) Offline auto-tuning

ON

ON

No Change

E5BE

A.9F

Execution Disable Error while Alarm Acti-
vated

Servo is in an alarm state. Clear alarm
before sending a SVON, servo ON, com-
mand.

ON

ON

No Change

9.2.2 Sigma II Indexer Error/Warning Status Display Table

Indexer

Status

Status

1

Code

Panel

2

Display

Detail

ALM

3

Output

/WARN

4

Display

Motor

Operation

Advertising