The following list shows parameters and their settings when used with the Sigma II Indexer
option unit.

Category

Parameter
Number

Name

Unit

Setting
Range

Default Set-
ting

Function
Selection
Parameters

Pn000

Function Selection Basic Switches
(See note 3).

0010

Pn001

Function Selection Application
Switches 1
(See notes 1 and 3).

0000

Pn002

Function Selection Application
Switches 2
(See note 3).

0000

Pn003

Function Selection Application
Switches 3

0002

Gain
Parameters

Pn100

Speed Loop Gain

Hz

1 to 2000

40

Pn101

Speed Loop Integral Time Constant

0.01ms

15 to
51200

2000

Pn102

Position Loop Gain

s

-1

1 to 2000

40

Pn103

Inertia Ratio

%

0 to 10000

0

Pn104

Not Used

Pn105

Not Used

Pn106

Not Used

Pn107

Bias

rpm

0 to 450

0

Pn108

Bias Width Addition

ref. units

0 to 250

7

Pn109

Feed-forward

%

0 to 100

0

Pn10A

Feed-forward Filter Time Constant

0.01ms

0 to 6400

0

Pn10B

Gain-related Application Switches
(See note 3).

0000

Pn10C

Mode Switch Torque Reference

%

0 to 800

200

Pn10D

Mode Switch Speed Reference

rpm

0 to 10000

0

Pn10E

Mode Switch Acceleration

10rpm/s

0 to 3000

0

Pn10F

Mode Switch Error Pulse

ref. units

0 to 10000

0

Pn110

Online Autotuning Switches (See
note 3.)

0010

Pn111

Speed Feedback Compensation
(See note 2).

%

1 to 100

100

Advertising