Monitor Modes

Appendix B-2

B.1 Monitor Modes

The following list shows monitor modes available via the CN7 port when using a digital operator

Table B.1: Monitor Modes

Digital
Operator
(CN7)

Content of Display

Unit

Remarks

Equivalent Serial

Command (CN6)

Un000

Actual Motor Speed

rpm

NFB or MON3

Un001

N/A

N/A

Un002

Internal Torque Reference

%

Value for

rated torque

TREF or MON5

Un003

Rotational Angle 1

Pulse

Number of

Pulses from

Origin

None

Un004

Electrical Angle 2

Degree

Angle from

Origin (elec-

trical)

None

Un005

SGDH Input Signal Monitor

IN1

Un006

SGDH Output Signal Monitor

OUT1

Un007

Input Reference Pulse Speed

rpm

NREF or MON4

Un008

Position Error

reference units

PER or MON2

Un009

Accumulated Load Rate

%

(1)

TRMS

Un00A

Regenerative Load Rate

%

(2)

RGRMS

Un00B

Power Consumed by DB Resistor

%

(3)

DBRMS

Un00C

SGDH Position Reference Counter

Display in

Hexadecimal

None

Un00D

PG Counter Feedback Pulse Counter

Display in

Hexadecimal

None

Un800

Last Error

ERR

Un801

NS600 Input Signal Monitor

IN2

Un802

NS600 Output Signal Monitor

OUT2

Un803

Status Flag Monitor

STS or MON6

Un804

Current Issue Position Monitor

reference units

PUN or MON1

Un805

Current Motor Position Monitor

reference units

PFB or MON7

Un806

Target Position Monitor

reference units

POS or MON8

Un807

Target Distance Monitor

reference units

DST or MON9

Un808

Registration Target Position Monitor

reference units

RPOS or MON10

Un809

Registration Target Distance Monitor

reference units

RDST or MON11

Advertising