Yaskawa Sigma II Indexer User Manual
Page 177

Sigma II Indexer User’s Manual
Sigma II Indexer Status Display Table
9-6
2.
The Panel Display is the built-in panel display on the SGDH Servo Amplifier. The panel display may
be deleted depending on the communication status between the SGDH and the JUSP-NS600.
3:
OFF: Output transistor is OFF = Alarm status
ON: Output transistor is ON = No alarm.
Alarms continue to keep their status until they are released.
4.
OFF: Output transistor is OFF= No error/warning.
ON: Output transistor is ON = Error/Warning Status.
Errors and Warnings are displayed for 2 seconds only.
5.
Some alarms cannot be reset by the panel display, digital operator, or serial command ARES. Elimi-
nate the cause of the alarm and then cycle the power supply to reset the alarms.
6.
A.9x is a SGDH Warning code. Refer to 8.3.1 SGDH Servo Amplifier Alarm Display Table.