Sigma II Indexer Status Display Table

9-6

2.

The Panel Display is the built-in panel display on the SGDH Servo Amplifier. The panel display may
be deleted depending on the communication status between the SGDH and the JUSP-NS600.

3:

OFF: Output transistor is OFF = Alarm status
ON: Output transistor is ON = No alarm.
Alarms continue to keep their status until they are released.

4.

OFF: Output transistor is OFF= No error/warning.
ON: Output transistor is ON = Error/Warning Status.
Errors and Warnings are displayed for 2 seconds only.

5.

Some alarms cannot be reset by the panel display, digital operator, or serial command ARES. Elimi-
nate the cause of the alarm and then cycle the power supply to reset the alarms.

6.

A.9x is a SGDH Warning code. Refer to 8.3.1 SGDH Servo Amplifier Alarm Display Table.