Mounting the Sigma II Indexer Application Module to an SGDH

1-7

4. For grounding, connect the ground wire of the Sigma II Indexer application module to the
point marked “G” on the SGDH servo amplifier. Refer to table 1.4 for the selection of the
proper screw size. Screws are provided with the application module.

Figure 1.7

Table 1.4: Sigma II Indexer Ground Wire Screw

Servo Amplifier

Screw

Note

SGDH-A3~02BE
SGDH-A3~10AE

M3x10

(round head phillips with split lock

washer and flat washer)

-

SGDH-15~50AE
SGDH-05~50DE

M4x10

(round head phillips with split lock

washer and flat washer)

-

SGDH-60~1EAE
SGDH-60~1EDE

M4x8

(round head phillips with split lock

washer and flat washer)

Use front panel side screw hole.