Yaskawa Sigma II Indexer User Manual

Page 178

Advertising
background image

Sigma II Indexer User’s Manual

Sigma II Indexer Status Display Table

9-7

9.2.2 Sigma II Indexer Error/Warning Status Display Table

Indexer

Status

Status

1

Code

Panel

2

Display

Detail

ALM

3

Output

/WARN

4

Display

Motor

Operation

Error

4

E41E

A.9F

Program Table Save Failure Error

ON

ON

No Change

E42E

A.9F

ZONE Table Save Failure Error

ON

ON

No Change

E43E

A.9F

JOG Speed Table Save Failure Error

ON

ON

No Change

E44E

A.9F

Program Table Checksum Error

ON

ON

No Change

E46E

A.9F

JOG Speed Table Checksum Error

ON

ON

No Change

E47E

A.9F

Serial Communication Receiving Buffer
Overflow Error

Buffer has a 100 command capacity. If over-
flow error occurs, then all commands stored
in the buffer are cleared.

ON

ON

No Change

E48E

A.9F

Serial Communication Parity Error

ON

ON

No Change

E49E

A.9F

Serial Communication Framing Error

ON

ON

No Change

E4AE

A.9F

Serial Communication Overrun Error

ON

ON

No Change

E4BE

A.9F

Moving Disable Error due to
P-OT

ON

ON

No Change

E4CE

A.9F

Moving Disable Error due to
N-OT

ON

ON

No Change

E4DE

A.9F

Moving Disable Error due to
P-LS

ON

ON

No Change

E4EE

A.9F

Moving Disable Error due to
N-LS

ON

ON

No Change

E4FE

A.9F

Position Reference “Out of Range” Error

ON

ON

No Change

E51E

A.9F

Position Non Reservation Error

A position must be reserved before a ST
command.

ON

ON

No Change

E52E

A.9F

Registration Distance Non Reservation
Error

A registration distance (RDST) must be
reserved before a RS command.

ON

ON

No Change

E53E

A.9F

Move Reference Duplication Error

New positioning move command sent
before previous commanded positioning
move complete. Previous commanded posi-
tioning move must be complete before com-
manding a new positioning move.

ON

ON

No Change

Advertising