Sigma II Indexer User’s Manual

Serial Command Functions

6-21

TRMppp = nnnnnnnn
[ppp: parameter number]
(0

d ppp d FFF)

Temporary Parameter Write

For applications where the online parameter is re-
written frequently during operation, use this com-
mand instead of PRMppp = nnnnnnnn.

Functions are the same (Number of write-in times is
limited on EEPROM physical characteristic).

Contents set by this command are returned to the
contents set by PRMppp = nnnnnnnn command at the
beginning by turning ON/OFF the control power sup-
ply or executing RES command.

Positive Response: OK

Negative Response:
ExxE

PRMINIT

Parameter Initialization

Returns parameter settings to setting at shipping.
Cycle control power OFF/ON or command RES to
enable setting.

Positive Response: OK

Negative Response:
ExxE

Table 6.7: Parameter Operation Commands

Serial Command

Function/Description

Answer