A.3 servo amplifier switches – Yaskawa Sigma II Indexer User Manual
Page 195

Sigma II Indexer User’s Manual
Servo Amplifier Switches
Appendix A-10
A.3 Servo Amplifier Switches
The following list shows the switches and their default settings.
Parameter
Digit
Place
Name
Setting
Description
Default
Setting
Pn000
Function
Selection
Basic
Switches
0
Direction
Selection
0
Sets CCW as forward direction.
0
1
Sets CW as forward direction (reverse rotation mode).
1
Control Method
1
Position control (pulse train reference).
1 (fixed)
2
Axis Address
0 to F
Sets servo amplifier axis address.
ADRS
3
Reserved
—
0
Pn001
Function
Selection
Application
Switches
0
Servo OFF or
Alarm Stop Mode
0
Stops the motor by applying dynamic brake (DB).
0
1
Stops the motor by applying dynamic brake (DB) and
then releases DB.
2
Makes the motor coast to a stop state without using the
dynamic brake (DB).
1
Not Used
—
—
0
2
AC/DC Power
Input Selection
0
Not applicable to DC power input: Input AC power
supply through L1, L2, and (L3) terminals.
0
1
Applicable to DC power input: Input DC power sup-
ply through (+)1 and (-) terminals.
3
Warning Code
Output Selection
0
ALO1, ALO2, and ALO3 output only alarm codes.
0
1
ALO1, ALO2, and ALO3 output both alarm codes and
warning codes. While warning codes are output,
ALM signal output remains ON (normal state).
Pn002
Function
Selection
Application
Switches
0
Not Used
—
—
0 (fixed)
1
Not Used
—
—
0
2
Absolute Encoder
Usage
0
Uses absolute encoder as an absolute encoder.
0
1
Uses absolute encoder as an incremental encoder.
3
Not used.
0
—
0 (fixed)