Sigma II Indexer Status Display Table
9-10
2.
The Panel Display is the built-in panel display on the SGDH Servo Amplifier. Operation panel dis-
play may be deleted depending on the communication status between SGDH and NS600.
3:
OFF: Output transistor is OFF = Alarm status
ON: Output transistor is ON = No alarm.
Alarms continue to keep their status until they are released.
4.
OFF: Output transistor is OFF= No error/warning.
ON: Output transistor is ON = Error/Warning Status.
Errors and Warnings are displayed for 2 seconds only.
5.
Over Travel and Software Limits continue to keep their status until they are released.
6.
P-OT/N-OT is detected by the JUSP-NS600. SGDH does not detect P-OT/N-OT signals, therefore
both “pot”/“not” is not displayed in the operation panel. Error is displayed on the JUSP-NS600 when
a moving reference is received.
7.
A.9x is a SGDH Warning code. Refer 7.3.2 SGDH Servo Amplifier Warning Display Table.