Sigma II Indexer User’s Manual

Program Table Mode (Mode 0)

5-49

5.7.4 Program (Index) Table Set-up

Table 5.6: Example program table

Program
Step

Target
Position

Positioning
Speed

Registration
Position

Registration
Speed

Programmable
Output

Event

Loop

Next
Step

0

A+100000

1000

250000

1000

NNNAA

IT0

1

1

1

I-200000

200

400000

2000

NNAA:

SEL3

2

127

2

+Infinite

4000

-

3000

ZZZZZ

IT1000 1

END

3

I+300000

500

-

4000

NA: ZZ

DT500

3

END

4

Stop

3000

-

5000

: : : : :

IT0

2

END

...

127

-

1000

100000

4000

AA: ZZ

IT0

5

END

Table 5.7: Functions of the program table

FUNCTION

Program Step

128 (0~127) available program steps.

All 128 (0~127) program steps can be addressed either by inputs /SEL0~/SEL6 or by serial command
STARTsss

Program steps can be repeated (see Loop) or linked together (see Next)

Target
Position

Setting:
I +/- 99999999

Relative position reservation [Reference Unit]

A +/- 99999999

Absolute position reservation [Reference Unit]

+Infinite

Equivalent to Jog Forward.

-Infinite

Equivalent to Jog Reverse.

Stop

Stop positioning.

-

No position reservation. Typically used for POUT reservation.

Setting at shipping:

Stop

Note:



r

Infinite will not work if software position reference limits, Pn81B and Pn81C, are used when Pn81A

= 0 (linear).

2. Cannot combine

r

Infinite with I +/- 99999999 or A+/- 99999999 unless a stop position reference is

specified after the

r

Infinite reference.

Positioning
Speed

Setting:

1 ~ 99999999

Speed reservation [x1000 Reference Unit/min.]

Setting at shipping:

1000