Sigma II Indexer User’s Manual

Absolute Encoders

5-37

5.6.3 Handling Batteries

In order for the absolute encoder to retain position data when the power is turned
OFF, the data must be backed up by a battery.

Installing the Battery at the Host Device (CN1 - 21, 22)

Lithium battery, by Toshiba: ER6VC3, 3.6V, 2000mAh

Battery Provided for Servo Amplifier (CN8)

Lithium battery: JZSP–BA01 (includes battery and connector)
Battery: Toshiba, ER3 V, 3.6V, 1000mAh

Figure 5.11 Battery Provided for Servo Amplifier

5.6.4 Absolute Encoder Setup

Perform the setup operation for the absolute encoder in the following circumstances:

• When starting the machine for the first time.

• When an encoder backup alarm is generated.

• When the servo amplifier’s power supply is turned OFF and the encoder’s cable is

removed.

The setup operation can be performed by using the hand-held digital operator, the
servo amplifier’s panel operator, or by serial command (see Appendix B2 Auxiliary
Functions
).

Install the battery at either the CN1-21, 22 or CN8, NEVER at both simultaneously.
Such a connection would create a circuit between the batteries, which could lead to electric shock, injury, or equipment dam-
age.

Battery carrying space

Batter connector (CN8)

WARNING