Table a.1: indexer parameters – Yaskawa Sigma II Indexer User Manual
Page 188

Sigma II Indexer User’s Manual
JUSP-NS600 Indexer Parameters
Appendix A-3
Pn807
/SEL1;/JOG0
(see note 1)
-
0 = Close = Program Select (Mode 0)
0 = Close = Jog Select (Mode 1)
1 = Open = Program Select (Mode 0)
1 = Open = Jog Select (Mode 1)
2 = Always Program Select (Mode 0)
2 = Always Jog Select (Mode 1)
3 = No Program Select (Mode 0)
3 = No Jog Select (Mode 1)
0
Pn808
/SEL2;/JOG1
(see note 1)
-
0 = Close = Program Select (Mode 0)
0 = Close = Jog Select (Mode 1)
1 = Open = Program Select (Mode 0)
1 = Open = Jog Select (Mode 1)
2 = Always Program Select (Mode 0)
2 = Always Jog Select (Mode 1)
3 = No Program Select (Mode 0)
3 = No Jog Select (Mode 1)
0
Pn809
/SEL3;/JOG2
(see note 1)
-
0 = Close = Program Select (Mode 0)
0 = Close = Jog Select (Mode 1)
1 = Open = Program Select (Mode 0)
1 = Open = Jog Select (Mode 1)
2 = Always Program Select (Mode 0)
2 = Always Jog Select (Mode 1)
3 = No Program Select (Mode 0)
3 = No Jog Select (Mode 1)
0
Pn80A
/SEL4;/JOG3
(see note 1)
-
0 = Close = Program Select (Mode 0)
0 = Close = Jog Select (Mode 1)
1 = Open = Program Select (Mode 0)
1 = Open = Jog Select (Mode 1)
2 = Always Program Select (Mode 0)
2 = Always Jog Select (Mode 1)
3 = No Program Select (Mode 0)
3 = No Jog Select (Mode 1)
0
Pn80B
/S-ON
(see note 1)
-
0 = Close = Servo ON
1 = Open = Servo ON
2 = Always Servo ON
3 = Always Servo OFF
0
Pn80C
P-OT
(see note 1)
-
0 = Open = Forward OT Status
1 = Close = Forward OT Status
2 = Always Forward OT Status
3 = Always Moveable
0
Pn80D
N-OT
(see note 1)
-
0 = Open = Reverse OT Status
1 = Close = Reverse OT Status
2 = Always Reverse OT Status
3 = Always Moveable
0
Pn80E
/DEC
(see note 1)
-
0 = Close = Zero-point Deceleration LS Start
1 = Open = Zero-Point Deceleration LS Start
2 = Always Zero-Point Deceleration LS Start
3 = No Zero-Point Deceleration LS Start
0
Table A.1: Indexer Parameters
Parameter
Number
Name
Unit
Setting Range
Default
Setting