Sigma II Indexer User’s Manual

Setting up the Reference Units

5-32

Ball Screws

Circular Tables

Belts and Pulleys

5.5.2 Setting Speed [x1000 Reference Units / min.]

The Sigma II Indexer stores all speed data in units of [X1000 Reference Units/min.]

Determine load (workpiece) speed in terms of 1,000 reference units per minute.

Example:

Reference Unit = 0.01 mm
Desired speed is 15 m/min.:
15,000 mm /min.

= 1,500,000 reference units / min.

0.01mm
Speed = 1,500 [x 1000 reference units / min.]

Preset
Values

Pn202

8192

Pn203

24000

Preset
Values

Pn202

24576

Pn203

3600

Preset
Values

Pn202

20,480

Pn203

1,309

Electronic gear ratio = = =

B
A

----

© ¹

§ ·

Pn202
Pn203

Travel distance per load shaft revolution = = 24000 ref units

2048

u 4 u 1

24000 x 1

0.24in.

0.00001in.

Electronic gear ratio = = =

B
A

----

© ¹

§ ·

Pn202
Pn203

Travel distance per load shaft revolution = = 3600 ref units

2048

u 4 u 3

3600 x 1

360°

0.1°

Load Shaft

Reference unit: 0.1°

Electronic gear ratio = = =

B
A

----

© ¹

§ ·

Pn202
Pn203

Travel distance per load shaft revolution = = 12,566.37 ref. units

16,384

u 4 u 3

12566.37

3.14

u 4 in.

0.0010in.

= =

196,608

12566.37

20,480

1,309

Reference unit: 0.0010in.
Load shaft

16-bit absolute encoder

Gear
ratio: 3:1

Pulley diameter

)4 in