1 specifications (cn6) – Yaskawa Sigma II Indexer User Manual

Page 131

Advertising
background image

Sigma II Indexer User’s Manual

Specifications (CN6)

6-2

6.1

Specifications (CN6)

Table 6.1: Specifications (CN6)

ITEMS

SPECIFICATIONS

Standard in complying with

RS232 / RS422 / RS485

Communication method

Asynchronous (ASYNC)

Baud rate

9600; 19,200; 38,400 Baud; (9,600 Baud setting at shipping)

Start bit

1 bit

Data

7 bits, ASCII Code

Parity

1 bit Even

Stop bit

1 bit

XON / XOFF Control

Not Available

DTR/SDR Control

Not Available

RTS/CTS Control

Not Available

Echo Back

Available