Table 3.7: cn4 input signals (sigma ii indexer), Table 3.8: cn4 output signals (sigma ii indexer) – Yaskawa Sigma II Indexer User Manual

Page 34

Advertising
background image

Sigma II Indexer User’s Manual

I/O Signals (CN1, CN4)

3-7

Table 3.7: CN4 Input Signals (Sigma II Indexer)

Signal Name

Pin No.

Function

+24V/COM

1

Control power supply input for sequence signals. User must provide the +24V power supply.
Minimum operating voltage: 11V
Maximum operating voltage: 25V

/Mode 0/1

3

Switches between Mode 0 and Mode 1.
Mode 0: Index table mode when ON.
Mode 1: Jog and homing mode when OFF.

/START-STOP;
/HOME

5

Mode 0: Starts selected index table program when ON. Stops program operation when OFF.
Mode 1: Starts homing routine when ON. Stops homing routing when OFF.

/PGMRES;/JOGP 7

Mode 0: Resets index table program when OFF

→ΟΝ

.

Mode 1: Forward jog enabled when ON. Stops forward jog when OFF

/SEL0;/JOGN

9

Mode 0: Program select input 0
Mode 1: Reverse jog enabled when ON. Stops reverse jog when OFF.

/SEL1;/JOG0

11

Mode 0: Program select input 1
Mode 1: Jog speed select input 0

/SEL2;/JOG1

13

Mode 0: Program select input 2
Mode 1: Jog speed select input 1

/SEL3;/JOG2

15

Mode 0: Program select input 3
Mode 1: Jog speed selected input 2

/SEL4;/JOG3

17

Mode 0: Program select input 4
Mode 1: Jog speed select input 3

Table 3.8: CN4 Output Signals (Sigma II Indexer)

Signal Name

Pin No.

Functions

/INPOSITION +

19

In-position: Turns ON when the position error is within the inposition window setting. Pn821
and when the commanded position profile has ended (also known as DEN, distribution end).

/INPOSITION -

20

/POUT 0+

21

Programmable Outputs

/POUT0-

22

/POUT1+

23

/POUT1-

24

/POUT2+

25

/POUT2-

26

/POUT3+

27

/POUT3-

28

/POUT4+

29

/POUT4-

30

Advertising