Yaskawa Sigma II Indexer User Manual

Page 50

Advertising
background image

Sigma II Indexer User’s Manual

Two-Step Trial Operation

4-5

also appear in red immediately at power-up if an alarm occurs. In this case, turn OFF
power and take appropriate action. See 8 Troubleshooting.

Note

If an absolute encoder is used, it must be set up. Refer to 5.6.4 Absolute Encoder Setup.

4. Operate with the Panel Operator.

Operate the servomotor using the Panel Operator. Check to see if the servomotor runs
normally. If using a servomotor with a holding brake, refer to 5.3.3 Using the Holding
Brake.

Jog Mode Operation

a) Press the MODE/SET key to select Fn002 in the auxiliary function mode.

b) Press the DATA/SHIFT key for a minimum of one second to select the Panel

Operator operation mode. Operation is now possible using the panel operator.

c) Press the MODE/SET key to set to the servo ON (with motor power turned

ON).

d) Press the Up Arrow

 or Down Arrow  key to operate the motor. The motor

keeps operating while the key is pressed.

e) Press the MODE/SET key to set to the servo OFF state (with motor power

turned OFF). Alternatively, press the DATA/SHIFT key for a minimum of one
second to set to the servo OFF state.

{

SGDM-

MODE/SET

DATA/

CHARGE

POWER

SERVOPACK

200V

YASKAWA

Motor Forward
Rotation

Motor Reverse
Rotation

Panel operator

Advertising