Table 6.10: monitors and functions – Yaskawa Sigma II Indexer User Manual

Page 157

Advertising
background image

Sigma II Indexer User’s Manual

Serial Command Functions

6-28

IN2

NS600 Input Signal Monitor

Positive Response:
IN2 = 01010101 [CR] [LF]
: Photocoupler OFF
1: Photocoupler ON
bit 0: MODE 0/1
bit 1: /START-STOP;/HOME
bit 2: /PGMRES;/JOGP
bit 3: /SEL0;/JOGN
bit 4: /SEL1;/OG0
bit 5: /SEL2;/JOG1
bit 6: /SEL3;/JOG2
bit 7: /SEL4;/JOG3
Note; Response sent as characters, not as one byte.

IN2TESTbbbbbbbb

NS600 Side Input Signal Reservation
(00000000

d bbbbbbbb

d 11111111)

0: Photocoupler OFF
1: Photocoupler ON
bit 0: /MODE 0/1
bit 1: /START-STOP;/HOME
bit 2: /PGMRES;/JOGP
bit 3: /SEL0;/JOGN
bit 4: /SEL1;/OG0
bit 5: /SEL2;/JOG1
bit 6: /SEL3;/JOG2
bit 7: /SEL4;/JOG3

Send IN2TESTEND to recognize
CN4 inputs.

Note: Sigma II Indexer inputs (CN4-
3, 5, 7, 9, 11, 13, 15, 17) are not rec-
ognized when the IN2TESTbbbbbbbb
command is used. Cycle power to re-
enable these inputs.

Positive Response: OK

Negative Response: ExxE

Return Error E56E when bbbbbbbb is less than 8 digits.

POUT

POUT Monitor

Positive Response: OK
POUT [SP] ANANA [CR] [LF]
A: output active
N: output inactive
Z: output dependent upon zone table
bit 0: /POUT 0
bit 1: /POUT 1
bit 2: /POUT 2
bit 3: /POUT 3
bit 4: /POUT 4

Table 6.10: Monitors and Functions

Serial Command

Function / Description

Answer