2 control configuration, 1 control overview, 2 serial communication parameters – Yaskawa Sigma II Indexer User Manual

Page 132

Advertising
background image

Sigma II Indexer User’s Manual

Control Configuration

6-3

6.2

Control Configuration

6.2.1 Control Overview

6.2.2 Serial Communication Parameters

The following parameters are used to set-up the communication protocol, baud rate and
command response.

Note: 1. For RS232 set Pn800 to 0 or 1
2. Echo Back is not available for global address, *, regardless of parameter setting.

3. Answer is not sent back for global address, *, regardless of parameter setting.

Table 6.2:

Single-Axis Control

Multi-Axis Control

Outline

Initial Set-
tings

ΠProtocol, Pn800
ΠBaud Rate, Pn801
ΠAxis Address, ADRS

ΠProtocol
ΠBaud Rate
ΠAxis Address

PARAMETER

DESCRIPTION

Setting

DEFAULT

Pn800

Protocol

0 = RS422 (RS232)
1 = RS422 + Echo Back (RS232 + Echo Back)
2 = RS485 Delimiter CR
3 = RS485 Delimiter CR + Echo Back per Character
4 = RS485 Delimiter CR + Echo Back per Command
5 = RS485 Delimiter CR LF
6 = RS485 Delimiter CR LF + Echo Back per Character
7 = RS485 Delimiter CR LF + Echo Back per Command

1

Pn801

Baud Rate

0 = 9,600
1 = 19,200
2 = 38,400

0

Pn802

Answer

0 = No Answer
1 = OK = Answer

1

#1

#2

Advertising