Table 6.6: moving command – Yaskawa Sigma II Indexer User Manual

Page 139

Advertising
background image

Sigma II Indexer User’s Manual

Serial Command Functions

6-10

SPDnnnnnnnn

Positioning Speed Reservation

Setting Range: 1

d nnnnnnnn d +99999999 [x1000 Reference Unit/min.]

Reserves speed reference. Default speed is set in parameter, Pn81E.
Speed reference value is the set value of parameter Pn81E when the power supply is turned
ON or RES command is executed.

Example:
Reference unit = 0.01mm: When desired position is 15m/min.;
1500mm/min. / 0.01mm =1,500,000 reference units/min.
= 1500 [X1000 reference units/min.]
SPD1500

Note: When reserving a new speed while positioning: the new speed is reserved with the fol-
lowing ST command.

Pos:
OK

Neg:
ExxE

ACCnnnnnnnn

Acceleration Reservation
(Equivalent to “TRM81F =”)

Setting Range: 1

d nnnnnnnn d 99999999 [x 1000 Reference Unit/min./ms]

Default acceleration is set in Pn81F.

Note: Smoothing Filter (Average Movement Filter) set by Pn208 = Movement

Averaging Time = 0 to 6400 [0.01 msec].

Pos:
OK

Neg:
ExxE

DECnnnnnnnn

Deceleration Reservation
(Equivalent to “TRM820 =”)

Setting Range: 1

d nnnnnnnn d 99999999 [x 1000 Reference Unit/min./ms]

Default deceleration is set in Pn820.

Pos:
OK

Neg:
ExxE

Table 6.6: Moving Command