Table 6.10: monitors and functions – Yaskawa Sigma II Indexer User Manual

Page 161

Advertising
background image

Sigma II Indexer User’s Manual

Serial Command Functions

6-32

MTTYPE

Motor Type Display

Positive Response:
MTTYPE = 00000001 [CR] [LF] (Display in Hexadecimal)

Voltage

Servomotor Model

00 = 100VAC

00 = SGMAH

01 = 200VAC

01 = SGMPH

02 = 400VAC

02 = SGMSH
03 = SGMG
06 = SGMUH

Negative Response: ExxE

MTSIZE

Motor Capacity Display
[x 10W]

Positive Response:
MTSIZE = 12345678 [CR] [LF] (Display in Hexadecimal)

Negative Response: ExxE

PGTYPE

PG Type Display

Positive Response:
MTSIZE = 00000110 [CR] [LF] (Display in Hexadecimal)

000D = 13-bit incremental
0011 = 17-bit incremental
0110 = 16-bit absolute
0111 = 17-bit absolute

Negative Response: ExxE

SVYSPEC

SGDH Y Spec. No. Display

Positive Response:
SVYSPEC = 12345678 [CR] [LF]

Negative Response: ExxE

SVVER

SGDH Software Version Display

Positive Response:
VER = 00001234 [CR] [LF] (Display in Hexadecimal)

Negative Response: ExxE

PGVER

PG Software Version Display

Positive Response:
VER = 00001234 [CR] [LF] (Display in Hexadecimal)

Negative Response: ExxE

TYPE

NS600 Type Code (0600H) Display

Positive Response:
TYPE = 00001234 [CR] [LF] (Display in Hexadecimal)

YSPEC

NS600 Y Spec. No. Display

Positive Response:
YSPEC = 12345678 [CR] [LF]

STIFF

Rigidity Monitor

Positive Response:
STIFF = 12345 [CR] [LF]

Negative Response: ExxE

STIFFd

Rigidity Reservation
(1

d d d 10)

Positive Response: OK

Negative Response: ExxE

Table 6.10: Monitors and Functions

Serial Command

Function / Description

Answer

Advertising