2 sigma ii indexer status display table, 1 sigma ii indexer alarm status display table – Yaskawa Sigma II Indexer User Manual

Page 175

Advertising
background image

Sigma II Indexer User’s Manual

Sigma II Indexer Status Display Table

9-4

9.2 Sigma II Indexer Status Display Table

9.2.1 Sigma II Indexer Alarm Status Display Table

Indexer

Status

Status

1

Code

Panel

2

Display

Detail

ALM

3

Output

/WARN

4

Display

Motor

Operation

Reset

5

Alarm

3

A.xx

A.xx

SGDH Alarm Activation Alarm

3

Follow

SGDH

OFF

Servo OFF

Follow

SGDH

CPF00

A.E0

Internal Flash Memory Alarm (Detected
only during initialization)

OFF

OFF

Servo OFF

NO

E12A

A.EF

Firmware Execution Alarm

OFF

OFF

Servo OFF

NO

E13A

A.EF

Firmware Version Unmatched (Only dur-
ing initialization)

Firmware version does not match hard-
ware version.

OFF

OFF

Servo OFF

NO

E14A

A.EF

Parameter Checksum Alarm (Detected
only during initialization)

OFF

OFF

Servo OFF

NO

E15A

A.EF

Parameter Version Unmatched (Detected
only during initialization)

Parameter version does not match firm-
ware version

OFF

OFF

Servo OFF

NO

E16A

A.EF

Parameter “Out of Range” Alarm
(Detected only during initialization)

Value set in parameter is out of range.
Example:
If Pn81D = Home Position exceeds
Pn81B= P-LS or Pn81C =N-LS when
Pn81A Moving Method = 1, 2 or 3, then
alarm E16A will occur.

OFF

OFF

Servo OFF

NO

E17A

A.E0

Initial Communication Alarm between
NS600 and SGDH (Detected only during
initialization)

Communication between SGDH and
NS600 failed during initialization.
Example:
In the case of an absolute encoder, if CN3
is being used at power-on, the alarm
E17A will occur. NS600 cannot get the
initial absolute position data from SGDH
when CN3 is in use.

OFF

OFF

Servo OFF

NO

E18A

A.E2

Communication (after initialization)
Alarm between NS600 and SGDH

Communication between SGDH and
NS600 failed. Watchdog timer checks
communication between NS600 and
SGDH.

OFF

OFF

Servo OFF

YES