1 transmission data format, 2 positive response format – Yaskawa Sigma II Indexer User Manual

Page 136

Advertising
background image

Sigma II Indexer User’s Manual

Transmission Data (Sigma II Indexer Æ Host Controller)

6-7

6.4

Transmission Data (Sigma II Indexer

o

Host Controller)

6.4.1 Transmission Data Format

Note:

1. Answers are displayed in all capital letters.
2. No answer is returned to a command when a parity error (E48E), framing error (E49E)

or overrun error (E4AE) is detected.

3. No answer is returned to a command when axis address ‘*’ (global command) is used.
4. No answer is returned if the wrong axis address is used.

6.4.2 Positive Response Format

No positive response, OK, returned when parameter Pn802=0.
Factory setting is Pn802=1 where a positive response, OK, is returned.

6.4.3 Negative Response Format

Note: [SP]: Space (ASCII Code 20h)

[CR]: Carriage Return (ASCII Code ODh)
[LF]: Line Feed (ASCII Code OAh)

AXIS NO.

DATA CHACARTER LINE

CR

LF

OK

OK [SP] [SP] [SP] [SP] [SP] [SP] [SP] [SP] [SP] [CR] [LF]

Other

ExxE [SP] [SP] [SP] [SP] [SP] [SP] [SP] [CR] [LF]

E56E

E56E [SP] ERR [SP] SN [CR] [LF]

E57E

E57E [SP] ERR [SP] PN [CR] [LF]

E58E

E58E [SP] ERR [SP] OV [CR] [LF]

Advertising