Table 5.14: use of zone table (example), Table 5.14a: zone table – Yaskawa Sigma II Indexer User Manual
Page 121
Advertising
Sigma II Indexer User’s Manual
Program Table Examples
5-66
Table 5.14: Use of ZONE Table (Example)
PGMSTEP
POS
SPD
RDST
RSPD
POUT
EVENT
LOOP
NEXT
0
A+500000
30000
-
1000
ZZZZZ
IT0
1
1
1
A+000000
30000
-
1000
ZZZZZ
IT0
1
0
Table 5.14a: Zone Table
ZONEN
ZONEP
ZONEN
ZONEP
0
0
0
16
+499995
+500004
1
+099995
+100004
17
0
0
2
+199995
+200004
18
0
0
3
0
0
19
0
0
4
+299995
+300004
20
0
0
5
0
0
21
0
0
6
0
0
22
0
0
7
0
0
23
0
0
8
+399995
+400004
24
0
0
9
0
0
25
0
0
10
0
0
26
0
0
11
0
0
27
0
0
12
0
0
28
0
0
13
0
0
29
0
0
14
0
0
30
0
0
15
0
0
31
0
0
Advertising