Table 6.10: monitors and functions – Yaskawa Sigma II Indexer User Manual

Page 160

Advertising
background image

Sigma II Indexer User’s Manual

Serial Command Functions

6-31

PGMSTEP

Program PGMSTEP Pass Through
Monitor

Displays the current program step in
progress

Positive Response:
PGMSTEP = + 12345 [CR] [LF]

EVTIME

Program EVENT Lapse of Time
Monitor
[ms]

Displays elapsed time of event condi-
tion time delay.

Positive Response:
EVTIME = + 12345 [CR] [LF]

LOOP

Program LOOP Pass Through Moni-
tor

Displays current loop of program step
in progress

Positive Response:
LOOP = + 12345 [CR] [LF]

TRMS

RMS Torque Monitor
[%]

Value for the rated torque as 100%.
Displays effective torque in 10 second
cycles.

Positive Response:
TRMS = +12345678 [CR] [LF]

Negative Response: ExxE

RGRMS

Regenerative Load Ratio Monitor
[%]

Value for the processable regenerative
power as 100%. Displays effective
power in 10 second cycles.

Positive Response:
RGRMS = +12345678 [CR] [LF]

Negative Response: ExxE

DBRMS

DB Load Ratio Monitor
[%]

Value for the processable power when
dynamic brake is applied as 100%.
Displays effective power in 10 second
cycles.

Positive Response:
DBRMS = +12345678 [CR] [LF]

Negative Response: ExxE

VER

NS600 Software Version Display

Positive Response:
VER = 00001234 [CR] [LF] (Display in Hexadecimal)

SVTYPE

SGDH Type Code (xx02H) Display

Positive Response:
SVTYPE: 00001234 [CR] [LF] (Display in Hexadecimal)

Negative Response: ExxE

Table 6.10: Monitors and Functions