Table 6.8: program table set-up – Yaskawa Sigma II Indexer User Manual

Page 154

Advertising
background image

Sigma II Indexer User’s Manual

Serial Command Functions

6-25

sss = Program Step
zz = Zone Table ID
dd = Jog Speed Table ID

Note: 1.

See also 5.7 Program Table Mode, 5.9 Zone Table, 5.11 Jog Speed Table for more details.

2. Changes to program table become effective immediately. Use the PGMSTORE command to save
the changes, otherwise the settings last saved by PGMSTORE will become effective on next power
ON or after RES command. The same holds true for Zone Table (ZONESTORE) and Jog Speed
Table (JSPDSTORE)

ZONEPTzz
(0

d zz d 31)

Zone table ZONEP (positive-side zone position limit) read.

Positive Response:
ZONEPT123 = +12345678 [CR] [LF]

Negative Response: ExxE

ZONEPTzz =
(0

d zz d 31)

Zone Table ZONEP (positive-side zone position limit) Write.

Setting:
-99999999 ~ +99999999 Zone position limit [reference unit]

Setting at shipping: 0

Positive Response: OK

Negative Response: ExxE

ZONENTzz
(0

d zz d 31)

Zone Table ZONEN (negative side zone position limit) Read.

Positive Response:
ZONENT123 = +12345678 [CR] [LF]

Negative Response: ExxE

ZONENTzz =
nnnnnnnn
(0

d zz d 31)

Zone Table ZONEN (negative side zone position limit) Write.

Setting:
-99999999 ~ +99999999 Zone position limit [reference unit]

Setting at shipping: 0

Positive Response: OK

Negative Response: ExxE

JSPDTdd
(0

d dd d 15)

Jog Speed Table JSPD (jog speed reservation) Read.

Positive Response:
JSPDT123 = +12345678 [CR] [LF]

Negative Response: ExxE

JSPDTdd =
nnnnnnnn
(0

d dd d 15)

JOG Speed Table Write

Jog Speed Table JSPD (jog speed reservation) Write.

Setting:
1 ~ 99999999 Jog speed [x1000 reference unit/min]

Setting at shipping: 1000

Positive Response: OK

Negative Response: ExxE

Table 6.8: Program Table Set-up