SGDH Servo Amplifier Status Display Tables

9-13

1.

OFF:Output transistor is OFF.
ON:Output transistor is ON.

2.

(*) These alarms are not reset by the panel display, digital operator, or serial command ARES. Elim-
inate the cause of the alarm and then turn OFF the power supply to reset the alarms.

3.

(

**

) This alarm display appears only within the range of 30 to 1000W.

9.3.2 SGDH Servo Amplifier Warning Display Table

The correlation between warning displays and warning code outputs is shown in the follow-
ing table.

Warning
Display

Warning Code Outputs

Warning Name

Meaning of Warning

ALO1

ALO2

ALO3

A.91

ON

OFF

OFF

Overload

This warning occurs before either of the
overload alarms (A.71 or A.72) occurs. If the
warning is ignored and operation continues,
a regenerative overload alarm may result.

A.92

OFF

ON

OFF

Regenerative
Overload

This warning occurs before the regenerative
overload alarm (A.32) occurs. If the warning
is ignored and operation continues, an over-
load alarm may result.

A.93

ON

ON

OFF

Low Battery

Low battery when used with an absolute
encoder.

A.9F

OFF

OFF

OFF

Indexer Error

Refer to 9.2.2 Sigma Indexer Error/Warning
Status Display Table