2 settings according to device characteristics, 1 switching servomotor rotation direction – Yaskawa Sigma II Indexer User Manual

Page 61

Advertising
background image

Sigma II Indexer User’s Manual

Settings According to Device Characteristics

5-6

5.2

Settings According to Device Characteristics

This section describes the procedure for setting parameters according to the dimensions and
performance of the equipment used.

5.2.1 Switching Servomotor Rotation Direction

The servo amplifier has a Reverse Rotation Mode that reverses the direction of ser-
vomotor rotation without rewiring. Forward rotation in the standard setting is
defined as counterclockwise as viewed from the load.

With the Reverse Rotation Mode, the direction of servomotor rotation can be
reversed without changing other parameters. Only the direction (+,

) of shaft

motion is reversed.

Setting Reverse Rotation Mode

Use the parameter Pn000.0.

Use the following settings to select the direction of servomotor rotation.

Standard Setting

Reverse Rotation Mode

Forward Reference

Reverse Reference

Parameter

Signal

Setting

Pn000.0

Direction Selection

Default Setting: 0

Setting

Description

0

Forward rotation is defined as counterclockwise
(CCW) rotation as viewed from the load.

(Standard setting)

1

Forward rotation is defined as clockwise (CW)
rotation as viewed from the load.

(Reverse Rotation Mode)

PBO (Phase B)

PBO (Phase B)