Sigma II Indexer User’s Manual

Two-Step Trial Operation

4-2

4.1

Two-Step Trial Operation

Make sure that all wiring is completed prior to starting trial operation.

Perform the trial operation in the order given below (step 1 and 2) for your safety. See 4.1.1
and 4.1.2
for more details on the trial operation.

Make sure the servomotor is wired properly and then turn the
shaft prior to connecting the servomotor to the equipment.

Check wiring.

C
N
3

C
N
1

L1C

L2C

B1

B2

U

V

W

L1

L2

1

2

C
N

2

SGDM-

MODE/SET

DATA/

CHARGE POWER

SERVOPACK

200V

YASKAWA

Do not connect to the equipment.

Adjust the servomotor according to equipment characteristics.
Connect the servomotor to the equipment, and perform the trial
operation.

SGDH
servo
amplifier

Connect to the equipment.

Adjust speed by autotuning.

Step 1: Trial Operation for Servomotor without Load

Step 2: Trial Operation with the Equipment and Servomotor Connected