Yaskawa Sigma II Indexer User Manual
Page 117

Sigma II Indexer User’s Manual
Zone Table Set-up
5-62
Setting Range: -99999999 ~ +99999999 reference units
Setting at Shipping: ZONE N = ZONE P = 0
Note: 1. Status of Z0~Z4 fixed for each zone.
2. Zone signals function only when the programmable outputs (/POUT0-/POUT4) are defined as a
zone output
o Z. Example: POUT = ZAZZN. Status of programmable outputs /POUT1, /POUT2,
and /POUT4 dependent upon zone table.
5.9.1 Zone Signal Conditions
1. ZONEN
dZONEP
Condition for Z0~Z4 true when ZONEN
d Current Position d ZONEP
2. ZONEID with lower number is used when the current position falls within multiple
zones (overlapping zones).
3. Z0~Z4 Non-Active when there is no ZONEN
d Current Position d ZONEP.
4. ZONEN > ZONEP:
Condition for Z0~Z4 true when Current Position
t ZONEN or Current Position
d ZONEP
For example: When position 0 is within a zone of a rotary application
Therefore, Z3 and Z2 active when current position is within ZONEID12.
5. ZONEN = ZONEP = 0:
Zone is not reserved.