6.5.6 Monitor and Function Commands

Table 6.10: Monitors and Functions

Serial Command

Function / Description

Answer

ALM

Alarm or Warning Read

Positive Response:
Returns one of the followings depending on its status:
ALM [SP]A. xx [SP] [CR] [LF] (xx: SGDH Alarm/Warning
Code)
ALM[SP] ExxA [SP] [CR] [LF] (ExxA: NS600 Alarm Code)
ALM [SP] P-OT [SP] [CR] [LF]
ALM [SP] N-OT [SP] [CR] [LF]
ALM [SP] P-LS [SP] [CR] [LF]
ALM [SP] N-LS [SP] [CR] [LF]
ALM [SP] BB [SP] [SP] [SP] [CR] [LF]
ALM [SP] HOLD [SP] [CR] [LF]
ALM [SP] INPOS [CR] [LF]
ALM [SP] NEAR [SP] [CR] [LF]
ALM [SP] RUN [SP] [SP] [CR] [LF]
ALM [SP]. [SP] [SP] [SP] [SP] [CR] [LF]

ALMn
(0

d n d 9)

Alarm History Read

Positive Response:
Returns one of the following:

ALM1 = NONE [CR] [LF] No Alarm.
ALM1 = A. xx [CR] [LF] Specific SGDH alarm.
ALM1 = ExxA [CR] [LF] Specific NS600 alarm.

Negative Response:
ExxE

ERR

Error Read
Displays only the latest error

Positive Response:
Returns one of the following:

ERR [SP] NONE [SP] [CR] [LF] No error.
ERR [SP] ExxE [SP] [CR] [LF] Specific error.

IN1

SGDH Input Signal Monitor

Positive Response:
IN1 = 01010101 [CR] [LF]
: Photocoupler OFF
1: Photocoupler ON
bit 0: /S-ON
bit 1: /SEL5
bit 2: P-OT
bit 3: N-OT
bit 4: /DEC
bit 5: /SEL6
bit 6: /RGRT
bit 7: 0 (fixed)
Note: Response sent as characters, not as one byte.