Advertising
background image

Sigma II Indexer User’s Manual

Serial Command Functions

6-20

6.5.3 Parameter Operation Commands

The following serial commands are used to monitor or re-write parameter contents.

Table 6.7: Parameter Operation Commands

Serial Command

Function/Description

Answer

PRMppp
[ppp: parameter number]
(0

d ppp d FFF)

Parameter Read

Contents of parameter ppp is sent from SGDH servo
amplifier.

(Example)

Command: 1PRM800
Response: 1PRM800=00000001

Positive Response:

Return PRM81B = + 12345678 [CR]
[LF] in coded decimal and 8 digits to
PRM81B, PRM81C,
PRM81D,PRM828.

Return PRM000 = 00001234 [CR] [LF]
in hexadecimal and 8 digits is back to
PRM000, PRM001, PRM002, PRM003,
PRM004, PRM005, PRM10B, PRM110,
PRM200, PRM207, PRM408, PRM50A,
PRM50B, PRM50C, PRM50D,
PRM50E, PRM50F, PRM510, PRM511
PRM512, PRM080.

Return PRM800 = 12345678 [CR] [LF]
in decimal and 8 digits to the serial com-
mands other than above.

Negative Response:
ExxE

PRMppp = nnnnnnnn
[ppp: parameter number]
(0

d ppp d FFF)

Parameter Write

Re-writes parameter with parameter number ppp to
(nnnnnnnn). For offline parameters, execute com-
mand RES after this command or cycle control power
OFF / ON.

Offline parameters:
Parameter is renewed only after RES command is
sent or control power supply is cycled after com-
mand.

Online parameters:
Parameter is renewed by parameter write-in com-
mand.

Parameters are stored in EEPROM, therefore the
contents are not erased if the control power supply is
turned off.
See also Appendix A Parameter List for details of
online and offline parameters.

Positive Response: OK

Negative Response:
ExxE