I/O Signals (CN1, CN4)

3-4

3.1.2 I/O Signals Connector (CN1, CN4)

The following diagrams show the layout of CN1 and CN4 terminals.

Table 3.1: CN1 Terminal Layout (Servo Amplifier)

Note

1.

Do not use unused terminals for relays.

2.

Connect the shield of the I/O signal cable to the connector shell.
The shield is connected to the FG (frame ground) at the servo amplifier-end connector.

1

SG

Signal

Ground

26

/WARN-

Servo warn-

ing output

2

SG

Signal

Ground

27

/BK+

Brake inter-

lock output

3

-

-

28

/BK-

Brake inter-

lock output

4

-

-

29

/S-RDY+

Servo ready

output

5

-

-

30

/S-RDY-

Servo Ready

Output

6

SG

Signal

Ground

31

ALM+

Servo alarm

output

7

-

-

32

ALM-

Servo alarm

output

8

-

-

33

PAO

PG Divided

Output

A-Phase

9

-

-

34

/PAO

PG Divided

Output

A-Phase

10

SG

Signal

Ground

35

PBO

PG Divided

Output

B-Phase

11

-

-

36

/PBO

PG Divided

Output

B-Phase

12

-

-

37

AL01

Alarm code

output
(open-

collector

output)

13

-

-

38

AL02

Alarm code

output

14

-

-

39

AL03

15

-

-

40

/S-ON

Servo ON

input

16

-

-

41

/SEL5

Program

select 5

17

-

-

42

P-OT

Forward

drive prohib-

ited input

18

-

-

43

N-OT

Reverse run

prohibited

input

19

PCO

PG Divided

Output

C-Phase

44

/DEC

Zero point

return decel-

eration LS

input

20

/PCO

PG Divided

Output

C-Phase

45

/SEL6

Program

select 6

21

BAT (+)

Battery (+)

46

/RGRT

Registration

latch

22

BAT (-)

Battery (-)

47

+24VIN

External

power sup-

ply input

23

-

-

48

PSO

S-Phase

Signal

Output

24

-

-

49

/PSO

S-Phase

Signal

Output

25

/WARN+

Servo warn-

ing output

50

-

-