Table 6.6: moving command – Yaskawa Sigma II Indexer User Manual

Page 144

Advertising
background image

Sigma II Indexer User’s Manual

Serial Command Functions

6-15

ZRN

Homing Start

Command to start zero-point return (homing) operation as shown below: Command only
used for incremental encoders. Homing routine defined in parameters Pn823-Pn828.

Pos:
OK

Neg:
ExxE

Zero-point Return Method

Operation Pattern

Mode 0 (Pn823=0)
None

No homing.

Mode I (Pn823 =1)
3-step deceleration method using
/DEC signal (decel LS) and C-
phase pulse signal

Mode II (Pn823 =2)
2-step deceleration method using
/DEC signal (decel LS) only

Mode III (Pn823 =3)
2-step deceleration method using
C-phase pulse only

Parameter
No.

Name

Unit

Pn823

Homing Method

0 = Mode 0 = No homing
1 = Mode I = /DEC and C-Phase
2 = Mode II = /DEC only
3 = Mode III = C-Phase only

Pn824

Zero-point return
direction

0: FWD direction
1: REV direction

Pn825

Zero-point feed-
ing speed

0 to 99999999

x1000 reference unit/
min.

Pn826

Zero-point return
approach speed

0 to 99999999

Pn827

Zero-point return
creep speed

0 to 99999999

Pn828

Zero-point return
final move dis-
tance

-99999999 to +99999999

reference unit

Table 6.6: Moving Command

Serial Command

Function / Description

Answer