Table 6.6: moving command – Yaskawa Sigma II Indexer User Manual

Page 141

Advertising
background image

Sigma II Indexer User’s Manual

Serial Command Functions

6-12

STI(±) nnnnnnnn
(+ can be omitted)

Positioning Start (Relative Position)

Setting Range: -99999999

d nnnnnnnn d +99999999 [Reference Units]

Command to perform positioning to relative (incremental) position reference.
Equivalent to POSI±nnnnnnnn

o ST

Note: Speed set by SPD command. If no SPD command given, then default speed set in
Pn81E is used.

Pos:
OK

Neg:
ExxE

RDSTnnnnnnnn

Registration Distance Reservation

Setting Range: 0

d nnnnnnnn d 99999999 [Reference Units]

Command to set (relative) registration distance.
Registration distance value becomes 0 when the power supply is turned OFF/ON or after
RES command is executed.

Pos:
OK

Neg:
ExxE

RSPDnnnnnnnn

Registration Speed Reservation

Setting Range: 1

d nnnnnnnn d 99999999 [x 1000 Reference Unit/min.]

Command to set registration speed.
Registration speed is set value of Pn81E when the power supply is turned OFF/ON or after
RES command is executed.

Pos:
OK

Neg:
ExxE

Table 6.6: Moving Command

Serial Command

Function / Description

Answer