Yaskawa Sigma II Indexer User Manual

Page 180

Advertising
background image

Sigma II Indexer User’s Manual

Sigma II Indexer Status Display Table

9-9

Notes:
1.

Status codes are displayed via the Sigma II Indexer JUSP-NS600. (CN7-digital operator, CN6-
response to serial commands ALM/ERR or denial response to other commands).

Error

4

E5CE

A.9F

Execution Disable Error while Main Power
OFF

Main power is off. Restore main power
before sending a SVON, servo ON, com-
mand.

ON

ON

No Change

E5DE

A.9F

Homing Method Non Reservation Error

No homing method is reserved. Set
Pn823 Homing Method = 1, 2 or 3.

ON

ON

No Change

E5EE

A.9F

Error during Program Operation

ON

ON

No Change

E5FE

A.9F

Session Conflict Error

Cannot execute a positioning command dur-
ing jog operation, etc.

ON

ON

No Change

E61E

A.9F

PG Non Coincide Error

1. Cannot execute absolute encoder specific

commands with an incremental encoder.

2. Cannot execute a homing routine with an

absolute encoder, etc.

ON

ON

No Change

E62E

A.9F

Error due to no A. CC (Multi-turn Limit was
executed without A. CC)

ON

ON

No Change

Warning

4

A.xx

A.9x

SGDH Warning Activation Warning

7

ON

ON

No Change

Over

Travel

5

Pot

bb or
run

P-OT

6

ON

OFF

Forward
Motion
Prohibited

not

bb or
run

N-OT

6

ON

OFF

Reverse
Motion
Prohibited

Software

Limit

5

PLS

bb or
run

P-LS

ON

OFF

Forward
Motion
Prohibited

nLS

bb or
run

N-LS

ON

OFF

Reverse
Motion
Prohibited

Normal

bb

bb

Servo OFF

ON

OFF

-

run

run

Servo ON

ON

OFF

-

9.2.2 Sigma II Indexer Error/Warning Status Display Table

Indexer

Status

Status

1

Code

Panel

2

Display

Detail

ALM

3

Output

/WARN

4

Display

Motor

Operation

Advertising