Using this command, specify the alarm message

(less than 32 characters) enclosed by 3-digit

alarm number n and control-in and control-out.
The alarm number should be three digits and be
the one that is not used by the machine.

When this #3000 command is executed, “ ALM”

is displayed on the bottom of CRT

screen regardless of the mode and function.

Its message can be seen by the following opera-

tion :

a. Depress

function key.

The alarm number and message are displayed

on the bottom of CRT screen.

ALARM

09100 N0054

USERS MESSAGE

550: MACRO ERROR: DATA OVERFLOW

I

“ALM “

1

Message display area and
sample display

b.

When

key is pressed after

of the

cause of alarm, the message display and the alarm state
can be cleared.

Sample Program

#3000 = 550 (

M A C R

O

D

A T

A

o v E R -

FLOW )

E.

Clock (#3001 , #3002)

When system variable #3001 or #3002 for

clock is specified, the clock can be read.

System

Type

At

‘nit

Power-On

Variable

Condition

#3001

Clock 1 1 ms

Reset to “ O“

A l w a y s

#3002

Clock 2 1 s

Same as

When STL

p o w e r - o f f

signal is on

time

To preset the clock, substitute the value

with this system variable put at the left-hand of
the expression.

Sample Program

=

o ; . . .

The clock is preset to value “ O.”

Restrictions

a.

The accuracy of clock is 8 ms. When

4294968000 msec has been reached, an overflow

occurs, setting the clock to O.

b .

The accuracy of clock 2 is 8 ms. When

429496800 sec has been reached, an overflow oc-

curs , setting the clock to

Sample Program

Argument designation

Program

of variable

““”

‘or

Macro

Program

09351 ;

#3002

o ;

WHILE [#3002 NE

;

END 1 ;

I

M99 ;

L

F.

Single Block Stop and Auxiliary Function

Completion Wait Control ( #3003)

when the value listed in the following table is substituted

in system variable #3003, the single block switch can be
disabled or the next block can be entered without waiting
for the checking of the finish signal (FIN) of the

function (MST].

When the finish signal is not waited for, the

distribution end signal (DEN) is not transmitted,
In this case, the FIN is waited for in the block
with the check skip cleared.

Hence, when the

FIN is not waited for, don’t specify the next
auxiliary function.

#3003

Signal

o

Valid

Waited

I n v a l i d

Waited

2

I

Valid

Not waited

3

I

Invalid

N o t w a i t e d

G. Feed-Hold, Feedrate-Override, and Exact-Stop Control
(#3004)

When the value listed in the following table is

substituted in system variable #3004, feed hold,
feedrate override, and exact stop can be made
valid or invalid.