Yaskawa J50M Instructions User Manual

Page 176

Advertising
background image

5.1.10 RAPID TRAVERSE RATE OVERRIDE SWITCH

This

is used to adjust the traverse rate by FO, 25,

50 and 100Yo.

rate is the rapid traverse rate set by

parameter #6280 to 6284.

The switch is effective both in automatic operation

including GOO command and in manual operation
(RAPID mode). FO is set by parameter #6231.

5.1.10.1 RAPID FEED OVERRIDE
SWITCH 2

(1) In the conventional function, override of the

four steps of

and

can be

commanded against the rapid feedrate.
This function is now expanded to allow override of

the six steps of

25%,

FO

,

and

(2) The

and

feedrates are the feedrates

given by the parameter (#6466, #6467).

5.1.11 FEEDRATE OVERRIDE SWITCH

In the automatic operation mode ( TAPE, MEM,
MDI) , this switch is used to adjust the feedrate
by 10% from O to 200% of the programmed feedrate
specified with an F function at whatever position
the switch may be set.

Feed during tapping by

G74 follows F command. Where OVERRIDE
CANCEL switch is set

the

be moved

at the programmed feedrate by F code regardless
of switch setting.

Table 5.4 Feedrate Override

STEP

STEP

0

0

11

110

1

10

12

2

20

13

3

30

14

140

4

40

15

150

16

160

17

170

7

70

18

180

8

80

19

190

9

21

200

10

100

OVERRIDE
CANCEL

I

FEEDRATE
OVERRIDE

Fig. 5.7

5.1.12 JOG FEEDRATE OVERRIDE SWITCH

1. This option permits overrides in 21 steps of
10% per step within a range of O to 200% in relation

to the jog feedrate.

2. This switch also serves as the “FEEDRATE

OVERRIDE” switch. When the JOG mode is selected.
the Feedrate Override switch becomes the Jog

Override switch.

JOG

PEEDRATE

OVERRIDE

&

FEEDRATE
OVERRIDE

100

200%

Fig. 5.8

3, Use this function as follows.

Although the Jog Feedrate switch can be switched
over in a maximum of 32 steps, this is limited
the three steps of LOW - MEDIUM - HIGH and the
intermediate speeds are compensated for with the

FEEDRATE

fUnCtion.

5.1.13 FEEDRATE OVERRIDE CANCEL SWITCH

Turning on the OVERRIDE CANCEL switch pre-
vents the function of FEEDRATE OVERRIDE switch.

5.1.14 SPINDLE SPEED OVERRIDE

1.

With this switch, the current spindle speed
can be changed to an override speed which
is set at 10% intervals between

50

and

of the current spindle speed.

2.

During the tapping cycle by G84 and G74,

the spindle speed may selectively be made
independent of this switch, remaining at the

speed set by

S code.

This selection is

made with the parameter

SPINDLE-SPEED

90

120%

50

Fig. 5.9

5.1.14.1

SPINDLE SPEED OVERRIDE SWITCH 2

Overview

The conventional function that allows

to 120%

override against the S command is expanded to
allow override of 10% to 200%.

168