Yaskawa J50M Instructions User Manual

Page 202

Advertising
background image

6.9 MDIOPERATION INTERRUPTING
AUTOMATIC OPERATION

(Cent’d)

4.

5.

6.

7.

Write the data referring to 4.3.3 WRITING IN

BLOCKS AND DISPLAYING CONTENTS BY

.

Set back MODE SELECT switch to the inter-
rupted automatic mode (TAPE or MEM) .

Return SINGLE BLOCK switch to OFF posi-
tion.

Depress CYCLE START button, and TAPE
or ‘MEM operation can be continued.

Notes :

, Writing data by MDI cannot be executed in tool radius

compensation modes (G41, G42) because two to four
blocks are read ahead. In principle, MDI operation
cannot interrupt.

However, F, M, S, T and

codes

can be output by the 6.7 MANUAL OPERATION
INTERRUPTING

OPERATION.

. Writing data by MDI should not be performed

in canned cycle modes

G74, G76, G77,

to G89) .

The machine may not operate

p r o p e r l y .

Tape mode

interrupting is available only

after completion of advance reading stop block
operation.

. Any other than described above are possible in

operation.

6.10 PREPARATION FOR TURNING OFF POWER

1.

2.

3.

Make sure that the machine is at standby and
CYCLE START lamp is extinguished.

Check to see that NC ALARM is not indicated

on CRT.

If alarm is displayed, detect the

causes of displayed alarm code and eliminate
them.

Refer to 4.3.12, DISPLAYING ALARM

CODE “.

Inspect the machine referring to the machine

builder’s manual.

6.11 TURNING OFF POWER

Depress EMERGENCY STOP pushbutton to

turn off the servo power supply.

2.

Depress POWER OFF pushbutton on the op-
erator’s panel to turn off the control power
supply .

3.

Cut off the main power supply from the con-
trol.

194