4.1.10 EDIT KEYS

These keys are for editing a stored part program.

ERASE key:

Used for erasure of data in storage.

INSRT key:

Used for insertion of data in memory

A L T E R k e y :

Used for alteration of data in

memory.

Fig. 4.9

4.1.11 MEM DATA (MEMORY DATA) KEYS

TAPE KEYs

are to start the tape operation except

in the automatic operation mode.

They are effec-

tive only in the EDT mode.

. OUT key

This key is to

outputting various data in

memory through data I /0

interface.

IN key

This key is to start storing various data into
memory through tape reader or data I /0 inter-

face.

. VER key

This key is to start verifying between memory
data and punched tape data.

4.1.12 RESET KEY

This key resets the control.

LTER

F i g .

4.10

Auxiliary function cancel

Label skip function ON

pointer rewind

Sequence number reset

RST signal transmission

G code

Refer to 2.9.1, “ LIST OF G CODES AND GROUPS .“

The following will not be affected by operating the
RESET key.

Current position values of each axis.

. F commands

. S, T and B commands

Tool offset values, setting data, parameter data

Note :

Depressing the RESET key or the re-

mote reset pushbutton is defined as “Reset

in this manual.

4.2

POWER ON/OFF OPERATION

4.2.1 TURNING ON POWER

Check the machine before turning on power,
ferrin g to the machine tool b

manual for

details.

Operations after completion of

-

tions are as follows.

Depress the POWER ON pushbutton to turn on
the control power.

The internal timer will be

read in about two seconds.

Then the servo

power is ready for turning on, which is shown
by alarm code “ 310. “

Depress the POWER ON pushbutton again to
turn on the servo power. The NRD (NC READ-
Y) signal is sent out when the NC power is
normally supplied.

When the NRD signal turns on the machine
power, and the MRD (MACHINE READY) sig-
nal returns back to the control, the READY
lamp will be lit.

Operations to be executed by this RESET key are:

. Move command cancel

. Buffer register clear

. Alarm code release if the cause is eliminated

. Tool offset cancel

137